When running downspout drain leads under a bed of dirt to move the water away from the foundation should one use that soft flex pipe or solid PVC pipe? I need to run about 12 feet.

Thanks
Top of pagePrevious messageNext messageBottom of page Link to this message

jgberkeley
Supporter
Username: Jgberkeley

Post Number: 3192
Registered: 5-2001
Posted on Monday, October 13, 2003 - 1:48 pm:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

I would suggest hard PVC. Use the one with out the holes. Make sure you have drain pitch, 3-4 inches for each 10 feet.

For many reasons.
Top of pagePrevious messageNext messageBottom of page Link to this message

Michael K. Mc Kell
Citizen
Username: Greenerose

Post Number: 54
Registered: 9-2003
Posted on Monday, October 13, 2003 - 3:48 pm:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

Agree with solid PVC.
Pitch is 1/4" per foot.
Michael K. Mc Kell
Top of pagePrevious messageNext messageBottom of page Link to this message

NRL
Citizen
Username: Nrl

Post Number: 246
Registered: 8-2003
Posted on Monday, October 13, 2003 - 6:53 pm:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

Thanks JG and MM.
I have 3x4 downspout. What would be the minimal size recommended for the underground PVC lead? I could reduce it at the bottom of the downspout to make it a little easier to bury the pipe but I am not sure if I should. Any recommendations?
Top of pagePrevious messageNext messageBottom of page Link to this message

Michael K. Mc Kell
Citizen
Username: Greenerose

Post Number: 56
Registered: 9-2003
Posted on Monday, October 13, 2003 - 7:21 pm:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

You can purchase the PVC ends where it fits nicely into the leeder.
If you bury the pipe it looks better.
If the pipe isn't seen and the pitch is ok, don't.
Michael K. Mc Kell
Top of pagePrevious messageNext messageBottom of page Link to this message

jgberkeley
Supporter
Username: Jgberkeley

Post Number: 3195
Registered: 5-2001
Posted on Monday, October 13, 2003 - 8:51 pm:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

The pipe you need is the 4" stuff. HD has a rack of the stuff with holes drilled in it, then above a rack with out the drain holes.
Top of pagePrevious messageNext messageBottom of page Link to this message

tjohn
Citizen
Username: Tjohn

Post Number: 1837
Registered: 12-2001


Posted on Monday, October 13, 2003 - 10:59 pm:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

Ask for Schedule 40 PVC, 4" diameter.
Top of pagePrevious messageNext messageBottom of page Link to this message

bobk
Supporter
Username: Bobk

Post Number: 3584
Registered: 5-2001
Posted on Tuesday, October 14, 2003 - 4:17 am:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

I am not sure that you want to use perforated pipe. The point of the exercise is to get the water away from the foundation. Also the perforated pipe is meant to be used in a drain field of some sort, buried in gravel.
Top of pagePrevious messageNext messageBottom of page Link to this message

jgberkeley
Supporter
Username: Jgberkeley

Post Number: 3196
Registered: 5-2001
Posted on Tuesday, October 14, 2003 - 9:15 am:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

Bobk,

I think you missed the words "with out".
Top of pagePrevious messageNext messageBottom of page Link to this message

bobk
Supporter
Username: Bobk

Post Number: 3587
Registered: 5-2001
Posted on Tuesday, October 14, 2003 - 9:25 am:   Edit PostDelete PostPrint Post   Move Post (Moderator/Admin Only)

Yep, memo to file: Make eye doctor appointment. :-)